      Description

      If GPII is closed abruptly, the pid file isn't removed.

      I've just had GPII read a stale pid file, and refuse to run because another process has re-used that pid.

      Current work-around: Delete the pid file.

      To-do: Also store the process creation time in the file, and check it against that of the running process.

       